For preliminary design only; verify with the adopted code edition and the authority having jurisdiction.
IBC 2021, Group B: 70 occupants
| Item | IBC section | Value | Metric |
|---|---|---|---|
| Design occupant load of the story | 1004.3, 1004.5 | 70 occupants | |
| Minimum exits or access to exits from the story | 1006.3.3, 1006.3.4 | 2 | |
| Stairway capacity factor per occupant | 1005.3.1 | 0.3 in | 7.6 mm |
| Stairway capacity, all stairways | 1005.3.1 | 21.0 in | 534 mm |
| Minimum stairway width | 1011.2 | 44 in | 1,118 mm |
| Width of each stairway, equal share | 1005.3.1, 1011.2 | 44.0 in | 1,118 mm |
| Doors, corridors and ramps: capacity factor per occupant | 1005.3.2 | 0.2 in | 5.1 mm |
| Doors, corridors and ramps: capacity, all exits | 1005.3.2 | 14.0 in | 356 mm |
| Minimum door clear opening width | 1010.1.1 | 32 in | 813 mm |
| Clear width of each exit door, equal share | 1005.3.2, 1010.1.1 | 32.0 in | 813 mm |
| Minimum corridor width | Table 1020.3 | 44 in | 1,118 mm |
| Corridor width for the whole story load | 1005.3.2, 1020.3 | 44.0 in | 1,118 mm |
| Accessible means of egress stairway, clear width between handrails | 1009.3.2 | 48 in | 1,219 mm |
| Space | Function | Size | Factor | Occupants | Exits |
|---|---|---|---|---|---|
| Open office | Business areas | 4,500 sq ft | 150 sq ft gross | 30 | 1 if common path is 100 ft or less, else 2 |
| Conference room | Assembly without fixed seats: unconcentrated (tables and chairs) | 600 sq ft | 15 sq ft net | 40 | 1 if common path is 75 ft or less, else 2 |
| Total (story) | 70 | Story: 2 (1006.3.3) |
Sources: IBC Sections 1004, 1005.3, 1006, 1009.3.2, 1010.1.1, 1011.2, 1020.3 (2021 and 2024 editions). Single exit stories (Section 1006.3.4) are flagged, but story level and travel distance are not checked. Mall buildings (Section 402.8.2) are not evaluated.
Occupant load is the number every egress design starts from: it decides how many exits a floor needs and how wide its stairs, doors and corridors must be. This occupant load calculator applies IBC Table 1004.5 space by space, adds the spaces of the story, then turns the total into egress capacity, minimum widths and the number of exits for the 2021 or 2024 edition. It is free, there is no sign up, and the calculation runs in your browser, so nothing you type is sent to a server.

Your inputs are kept on this device. The page opens with the default example; when saved inputs are found, a “Restore” link brings them back.
The default example shows the arithmetic. A 4,500 sq ft open office at 150 sq ft gross gives 30 occupants. A 600 sq ft conference room with tables and chairs at 15 sq ft net gives 40. The story total is 70. At 0.3 in per occupant the stairways need 21.0 in of capacity in total, and at 0.2 in the doors and corridors need 14.0 in. Both are below the minimum widths, so each stairway is 44 in, each exit door 32 in clear, the corridor 44 in, and the story needs 2 exits.
Every factor in Table 1004.5 is marked gross or net, and the tool prints the IBC Chapter 2 definitions in its notes. Gross floor area is measured inside the exterior walls, without deducting corridors, stairways, closets, interior walls or columns; business, mercantile and residential factors are gross. Net floor area leaves out corridors, stairways, ramps, toilet rooms, mechanical rooms and closets; assembly, classroom and day care factors are net. Type the area that matches the factor, or the occupant load comes out higher than the code asks for.
The calculator lists every row of the table that has a factor, plus fixed seats, benches, booths, bowling lanes and an actual head count where the building official approves one. These come up most often (sq ft per occupant):
| Function of space | Factor |
|---|---|
| Business areas | 150 gross |
| Concentrated business use areas (1004.8) | 50 gross |
| Mercantile | 60 gross |
| Assembly without fixed seats, concentrated (chairs only) | 7 net |
| Assembly without fixed seats, standing space | 5 net |
| Assembly without fixed seats, unconcentrated (tables and chairs) | 15 net |
| Educational, classroom area | 20 net |
| Educational, shops and vocational rooms | 50 net |
| Day care | 35 net |
| Exercise rooms | 50 gross |
| Kitchens, commercial | 200 gross |
| Residential | 200 gross |
| Accessory storage areas, mechanical equipment room | 300 gross |
| Warehouses | 500 gross |
The only change between the 2021 and 2024 tables is a new row in 2024: information technology equipment facilities at 300 sq ft gross. If you pick it while the edition is set to 2021, the calculator tells you the row is not in that edition.
Once the story total is known, Section 1005.3 turns people into inches.
With only the sprinkler box ticked, or with both boxes ticked in Group H or I-2, the calculator keeps the full factors and a warning says why. Run the default example sprinklered with a voice alarm and the stairway capacity drops from 21.0 in to 14.0 in, the other components from 14.0 in to 10.5 in.

The tool divides the capacity by the number of exits for an equal share, never less than the minimum width. Section 1005.5 adds a check you have to make on the plan: where more than one exit is required, losing any one of them shall not reduce the available capacity below 50 percent of the required capacity.
Capacity is only half of the answer. Each component also has a fixed minimum, and the required width is whichever is larger.
| Component | Minimum | Section |
|---|---|---|
| Stairway | 44 in (1118 mm); 36 in (914 mm) when serving fewer than 50 occupants | 1011.2 |
| Corridor, general | 44 in; 36 in for an occupant load of less than 50 | Table 1020.3 |
| Corridor, Group E with 100 or more occupants | 72 in | Table 1020.3 |
| Corridor with stretcher traffic in ambulatory care | 72 in | Table 1020.3 |
| Corridor, Group I-2 where needed for bed movement | 96 in | Table 1020.3 |
| Door clear opening | 32 in (813 mm); 41 1/2 in (1054 mm) for Group I-2 doors used to move beds | 1010.1.1 |
| Accessible means of egress stairway, clear width between handrails | 48 in (1219 mm), not required in a sprinklered building | 1009.3.2 |
The corridor line uses the whole story load. For the background on corridor dimensions in other codes and in accessible design, see our guide to minimum corridor width. Stair geometry beyond width, such as riser height and tread depth, is covered in minimum stair dimensions, and leaf sizes in standard door sizes. The wider corridors and doors that Group I-2 needs for moving beds are part of the wider brief covered in our article on standards for healthcare facility design.
The calculator answers this at two levels, because the IBC does.
Table 1006.3.3 sets the minimum by the occupant load of the story: 1 to 500 occupants need 2 exits, 501 to 1,000 need 3, and more than 1,000 need 4. Section 1006.3.4 allows a single exit in some cases, and the tool flags them.
The calculator does not know the story level or the travel distance, so a single exit is shown as “may be permitted”. You confirm both on the plan.
Table 1006.2.1 decides whether a room can have one exit or exit access doorway. A space needs two when its load is over the maximum for the group, or when the common path of egress travel is longer than the limit. Above 500 occupants Section 1006.2.1.1 asks for 3, and above 1,000 for 4.
| Group | Max. load for one exit | Common path, not sprinklered | Common path, sprinklered |
|---|---|---|---|
| A, E, M | 49 | 75 ft | 75 ft |
| B | 49 | 100 ft (30 or fewer occupants), 75 ft (over 30) | 100 ft |
| S | 29 | 100 ft (30 or fewer), 75 ft (over 30) | 100 ft |
| R-2 | 20 | not permitted | 125 ft |
| R-3, R-4 | 20 | not permitted | 125 ft |
In the default example the open office of 30 reads “1 if common path is 100 ft or less, else 2” and the conference room of 40 reads “1 if common path is 75 ft or less, else 2”. You measure the common path; the tool gives you the limit to measure against.

Group R-3 has one more rule. Table 1006.2.1 note e applies the common path limit to R-3 only in a mixed occupancy building. So an R-3 space of up to 20 occupants is shown with 1 exit in a single occupancy R-3 building, and the same row tells you that in a mixed occupancy building it needs 2 without sprinklers, or 1 if the common path is 125 ft or less with sprinklers. Over 20 occupants it needs 2. In Group R-4 a one exit space needs sprinklers.
As the tool itself says: for preliminary design only; verify with the adopted code edition and the authority having jurisdiction.
When the occupant load is settled, the same number drives the restroom count. The plumbing fixture calculator can pick up the total you calculated here with one click, in the same browser.
Divide the floor area of each space by its occupant load factor from IBC Table 1004.5, round each result up to the next whole person, and add the spaces of the story.
Business areas use 150 sq ft gross per person. Concentrated business use areas, such as a call center, use 50 sq ft gross under Section 1004.8.
At least 0.3 in per occupant served, or 0.2 in in a building that is sprinklered throughout and has an emergency voice/alarm communication system (not in Group H or I-2). It is never less than 44 in, or 36 in when the stair serves fewer than 50 occupants.
When a story, or a single space, has 501 to 1,000 occupants. Above 1,000 you need four.
Yes. Section 1006.3.4 permits a Group R-3 story to have one exit or access to a single exit. Each space still follows Table 1006.2.1: in a single occupancy R-3 building a space of up to 20 occupants needs one exit, while in a mixed occupancy building the same space needs two without sprinklers. Many one and two family dwellings are built under the International Residential Code instead, so check which code applies.
Yes. Choose m², m and mm and enter areas in square metres. The egress table gives every width in both inches and millimetres.