Only zones with published limits are drawn. Hot points outside every cooling zone need air conditioning. Design guidance, not a comfort compliance check.
A bioclimatic chart shows how far each month of a climate sits from comfort, and which passive strategies could close the gap. This bioclimatic chart generator draws every month as a line from the cool morning to the warm afternoon, on the Givoni building bioclimatic chart or on the Olgyay chart, and tells you how much of each line falls in each strategy zone. Load the climate from NASA POWER, open an EPW weather file or type your own monthly values; the chart is calculated in your browser, and an EPW file is read on your device, never uploaded.
The Olgyay chart comes from Victor Olgyay’s Design with Climate (1963). It plots outdoor conditions, relative humidity across the bottom and dry bulb temperature up the side, against a comfort zone, and shows what is needed to get back to it: sun when it is too cool, wind when it is too warm.
Baruch Givoni’s building bioclimatic chart, first published in 1969 and revised in 1992, works on a psychrometric chart instead: dry bulb temperature along the bottom, humidity ratio in grams of water per kilogram of dry air up the side, with the relative humidity curves drawn across. Its zones are not about the body outdoors but about the building: how far natural ventilation, thermal mass, evaporative cooling or passive solar heating can bring the indoor climate back to comfort when the outdoor air is not.
For building design the Givoni chart is usually the more useful, because its zones name a design move.
A single average hides the swing between night and day, so the generator follows Givoni’s method and draws each month as a line between two points. One end is the mean daily maximum with the humidity at that time of day. The other end is the mean daily minimum with the humidity at that time. In most climates the warm end is also the dry end, because the same amount of water vapour gives a lower relative humidity in warmer air.
Where the humidity comes from depends on the data source.
The zone limits are Givoni’s 1992 values for hot and developing countries, as given by Lamberts, Dutra and Pereira in Eficiência Energética na Arquitetura (3rd edition, 2014). Each zone is numbered on the chart and in the legend.
The dashed line at 20 °C is the shading line: to the right of it, sun on the glazing is a gain you do not want. Zones 1 and 6 overlap between 18 and 20 °C, as they do in the source, so a cool spring month can be both comfortable and a candidate for solar heating.
The Olgyay chart in this tool uses the metric version of his comfort zone published by Katafygiotou and Serghides (2015), after Georgiadou and colleagues (1996).
Olgyay’s original chart in degrees Fahrenheit also has a sloping upper edge and extra curves for wind, moisture and radiation. Those could not be checked against the primary source, so only the limits published as numbers are drawn.
The share of a zone is the share of the monthly line that lies inside it. Each line is sampled at 101 points between its two ends. Because the zones overlap, the shares in a month can add up to more than 100%: a point at 30 °C and 40% relative humidity, for instance, sits in natural ventilation, in thermal mass with night ventilation and in evaporative cooling at once. Treat overlaps as a choice of strategies, not a double count.
A long line tells you the month has a large daily range: a climate where thermal mass pays off, because the building can carry the warmth of the afternoon into the night, or the coolth of the night into the day. A short line means day and night are similar, typical of humid coasts and the tropics, where air movement does most of the work. Each end of the line is a monthly mean, so the hottest afternoons sit beyond the warm end.
Points that fall outside every zone are reported as Outside all zones. On the hot side of the Givoni chart that means no passive cooling strategy in the chart reaches comfort and mechanical cooling is needed. On the Olgyay chart, very hot or very humid points fall in the Beyond wind cooling zone instead.
The chart tells you which strategies the climate rewards; the next step is the geometry. The sun path diagram generator shows when the sun reaches the glazing you want to heat or shade, and the wind rose generator shows whether there is a breeze to use for ventilation, from which direction and in which season. For the monthly temperature and rainfall picture that usually opens a climate analysis sheet, use the climate graph generator.
A hot dry climate typically shows summer lines running into thermal mass with night ventilation and evaporative cooling: heavy construction, courtyards and small shaded openings. A warm humid climate shows short lines high on the chart, in natural ventilation: light construction, deep shade and plans that let the wind through. A temperate or cold climate shows most of the year left of the shading line, in the solar heating zones.
The psychrometric chart is drawn with the equations in the ASHRAE Handbook Fundamentals (2017), chapter 1: the Hyland and Wexler saturation vapour pressure over ice and over water, the humidity ratio, the wet bulb temperature and the standard atmosphere pressure for a given elevation. When you choose site elevation, the elevation comes from the NASA POWER reply or from the EPW header; for typed values the chart stays at sea level. Zone boundaries are sampled in 0.1 °C steps, so the humidity and wet bulb limits stay curved.
The psychrometric functions were checked against PsychroLib 2.5 (Meyer and Thevenard, 2019). Saturation vapour pressure agreed to within 0.01% at 14 temperatures, the humidity ratio to within 0.0000001 kg/kg and the wet bulb temperature to within 0.01 K in ten test cases each.
It describes the outdoor climate, not the comfort inside a particular building, which depends on glazing, mass, insulation, ventilation and use and needs a thermal simulation. The chart is for early design: it tells you which strategies are worth testing.
Only zones with published numeric limits are drawn. The thermal mass for cooling zone, which the source gives only as a figure, is left out, and no air conditioning zone is drawn: hot points outside every passive zone are simply reported as outside all zones.
NASA POWER values are grid averages of roughly half a degree, not station measurements. If you have a better local source, load an EPW file from climate.onebuilding.org or type the station values.
The Olgyay chart plots outdoor temperature against relative humidity around a comfort zone, with sun and wind as the corrections. The Givoni chart plots the same months on a psychrometric chart and adds zones for building strategies such as natural ventilation, thermal mass and passive solar heating.
On the Givoni chart, Givoni’s 1992 limits for hot and developing countries: 18 to 29 °C and 20 to 80% relative humidity, between 4 and 17 g/kg. On the Olgyay chart, 21 to 27.5 °C and 30 to 65% relative humidity. The source of each chart is printed under it.
From the NASA POWER hourly mean day of each month, from the hour of each day’s maximum in an EPW file, or from the number you type. The method section above explains each case.
The source gives no separate numeric limit for it. Hot points outside every passive cooling zone, beyond 44 °C dry bulb or 24 °C wet bulb on the Givoni chart, are reported as outside all zones: that is where air conditioning is needed.
Yes. Choose Type monthly values and fill in, for each month, the mean daily maximum, the humidity at the maximum, the mean daily minimum and the humidity at the minimum.
No. It is a climate screening chart that shows which passive strategies suit the site. Indoor comfort in a specific design needs a simulation.